Pitot Tube Setup For Fluid Mechanics Lab
Pitot Tube Setup For Fluid Mechanics Lab

Pitot Tube Setup For Fluid Mechanics Lab

MOQ : 1 Piece

Pitot Tube Setup For Fluid Mechanics Lab Specification

  • Capacity
  • 15 Liters
  • Measurement Range
  • 0-1.2 m/s (velocity)
  • Model No
  • FM-PT01
  • Accuracy
  • 1% of Full Scale
  • Core Components
  • Pitot Tube, Water Circulating Pump, Manometer, Flow Measuring Tank, Sump Tank
  • Feature
  • Corrosion Resistant, Portable, Easy-to-Operate
  • Automation Grade
  • Manual
  • Frequency
  • 50 Hz
  • Temperature Range
  • Ambient
  • Voltage
  • 230 V AC Single Phase
  • Power Source
  • Electric
  • Equipment Materials
  • Mild Steel Powder Coated, Stainless Steel, Acrylic
  • Type
  • Pitot Tube Experimental Setup
  • Usage
  • Fluid Mechanics Laboratory, Educational Purpose
  • Display Type
  • Manometer Scale
  • Dimension (L*W*H)
  • 900 mm x 400 mm x 900 mm
  • Weight
  • Approx. 35 Kg
  • Material of Pitot Tube
  • Stainless Steel
  • Pipe Material
  • PVC/SS
  • Manometer Liquid
  • Mercury/Water
  • Flow Collection Tank Capacity
  • 25 Liters
  • Water Circulating Pump Capacity
  • 0.5 HP
  • Safety Features
  • Overload Protection for Pump
  • Flow Control
  • Provided with By-Pass Valve
  • Sump Tank Capacity
  • 40 Liters
  • Application
  • Measurement of Fluid Velocity Distribution
  • Number of Manometer Tubes
  • 1
 
 

About Pitot Tube Setup For Fluid Mechanics Lab


PiTOT TUBE SETUP APPARATUS:


To find the point velocity at the centre of a tube for different flow rates of water and calibrates the pitottube.To Pitot velocity profile across the across the cross section of pipe.Flow measurement- using tank 40 lrts Sump tank- capacity 70 ltrs



Precision Fluid Velocity Measurement

This experimental setup utilizes a stainless steel pitot tube connected to a manometer scale, allowing students and researchers to determine fluid velocity distribution with high accuracy. The apparatus achieves measurement ranges between 0 and 1.2 m/s, ensuring reliable results for laboratory analysis.


Robust and Safe Construction

Composed of corrosion-resistant materials including powder-coated mild steel and acrylic, the FM-PT01 is built for longevity. The water circulating pump features overload protection, while flow control is facilitated by a by-pass valve for safe and hassle-free operation under varied conditions.

FAQ's of Pitot Tube Setup For Fluid Mechanics Lab:


Q: How is the fluid velocity measured using the Pitot Tube Setup?

A: Fluid velocity is determined by inserting the stainless steel pitot tube into the flow path. The pressure difference between the stagnation and static points is displayed on the manometer scale, allowing calculation of velocity through established fluid mechanics principles.

Q: What is the capacity of the water circulating pump and the flow collection tank?

A: The setup includes a water circulating pump with a capacity of 0.5 HP and a flow collection tank with a capacity of 25 liters. The sump tank holds 40 liters, providing ample fluid volume for continuous experiments.

Q: When should the by-pass valve be used in this setup?

A: The by-pass valve is utilized to control the flow rate during experiments. Adjusting it helps maintain optimal fluid velocity and ensures precise measurement without overloading the pump.

Q: Where can the Pitot Tube Experimental Setup FM-PT01 be used?

A: This setup is ideal for placement in fluid mechanics laboratory environments, especially within universities, engineering colleges, and research centers involved in educational and experimental activities.

Q: What safety features are incorporated in the equipment?

A: The apparatus is equipped with overload protection for the water circulating pump, ensuring safe operation. Sturdy material construction further enhances safety by minimizing corrosion and operational failures.

Q: How does the manometer work, and which liquids are compatible?

A: The manometer displays the pressure differential using either mercury or water as the manometer liquid. This visual indication supports accurate velocity calculation and can be adjusted according to experiment requirements.

Q: What are the benefits of using the FM-PT01 Pitot Tube Setup?

A: Benefits include reliable measurement accuracy (1% of full scale), portability, ease of operation, corrosion resistance, and suitability for various educational experiments-making it a valuable asset for fluid mechanics learning.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Fluid Mechanics Lab Category

Free and Force Vortex Apparatus For Fluid Mechanics Lab

Free and Force Vortex Apparatus For Fluid Mechanics Lab

Minimum Order Quantity : 1 Piece

Voltage : 220240V AC

Dimension (L*W*H) : 850 mm x 600 mm x 1200 mm

Equipment Materials : Stainless Steel Tank, Acrylic Chamber, Mild Steel Frame

Temperature Range : Ambient to 50C

Bernoullis Theorem Apparatus For Fluid Mechanics Lab

Bernoullis Theorem Apparatus For Fluid Mechanics Lab

Minimum Order Quantity : 1 Piece

Dimension (L*W*H) : 482048 Inch (in)

Material : SS

Equipment Materials : Stainless Steel

Temperature Range : Room Temperature Celsius (oC)

Metacentric Height Apparatus For Fluid Mechanics Lab

Metacentric Height Apparatus For Fluid Mechanics Lab

Minimum Order Quantity : 1 Piece

Dimension (L*W*H) : Pontoon Size 300 x 150 Millimeter (mm)

Material : Stainless Steel

Equipment Materials : Front made of glass/perspex and stainless steel

Hydraulic  Bench Apparatus For Fluid Mechanics Lab

Hydraulic Bench Apparatus For Fluid Mechanics Lab

Minimum Order Quantity : 1 Piece

Voltage : 220 Volt (v)

Material : Stainless Steel



Back to top