Melting Point Apparatus Automatic
Melting Point Apparatus Automatic

Melting Point Apparatus Automatic

Melting Point Apparatus Automatic Specification

  • Accuracy
  • ±1°C
  • Temperature Range
  • Room temperature to 320°C
  • Frequency
  • 50 Hz
  • Power Source
  • Electrical, corded
  • Model No
  • Automatic-MPA-2024
  • Automation Grade
  • Automatic
  • Capacity
  • 3 samples simultaneously
  • Voltage
  • 220V AC
  • Measurement Range
  • Ambient to 320°C
  • Feature
  • Programmable ramp rates, Digital Temperature Setting, In-built cooling fan, Audible alert on melting
  • Core Components
  • Microprocessor controlled system, Display, Heating block
  • Equipment Materials
  • Stainless Steel Body with Powder Coating
  • Type
  • Automatic Melting Point Apparatus
  • Usage
  • Melting point determination of chemicals and pharmaceutical substances
  • Display Type
  • Digital LCD display
  • Dimension (L*W*H)
  • 305 x 220 x 310 mm
  • Weight
  • approx. 7-8 kg
  • Light Source
  • Built-in LED illumination for sample visibility
  • Interface
  • RS232/USB connectivity for data logging
  • Calibration
  • User-calibratable
  • Printer Port
  • Yes
  • Safety Feature
  • Overheat protection and error messaging
  • Heating Rate
  • Selectable (0.5°C - 10°C per minute)
  • Timer
  • Digital timer integrated
  • Sample Capacity
  • 3-4 capillary tubes
  • Data Storage
  • Yes, internal memory up to 50 results
 
 

Melting Point Apparatus Automatic About

Auto Melting Point Apparatus is fabricated using the latest microcontroller technology and advanced engineering techniques. It features microcontroller based digital display and soft touch membrane type keys ensuring accurate display of results and easy operation. Also, Auto Melting Point Apparatus has programmable plateau temperature and heating ramp rates. Further, Auto Melting Point Apparatus facilitates storage of up to 100 results.

Features :

  • Easy to operate
  • 4 digit seven segment LED display
  • Programmable plateau temperature
  • Programmable ramp rates
  • Storage up to 100 results
  • Quick cooling with integrated fan
  • Audio visual indicators for system status


Advanced Sample Capacity and Efficient Workflow

This apparatus allows the simultaneous testing of three to four capillary tubes, improving laboratory throughput and minimizing wait times. Its programmable ramp rates, digital temperature settings, and audible alerts streamline melting point measurements for quick, reproducible results.


Reliable Connectivity and Data Management

Equipped with RS232/USB interface and printer port, the instrument enables hassle-free data logging and result export. Internal storage for up to 50 melting point results ensures comprehensive documentation and easy retrieval during audits or analysis.


Enhanced Safety and User Convenience

User safety is prioritized with overheat protection, error messaging, and an in-built cooling fan. The apparatus features a stainless steel powder-coated body, digital LCD screen for clear monitoring, and LED illumination for optimal sample visibility, aiding precise observation during analysis.

FAQ's of Melting Point Apparatus Automatic:


Q: How does the Automatic Melting Point Apparatus determine melting points of samples?

A: The apparatus uses up to three capillary tubes loaded with samples, heats them at a programmable rate, and displays melting observations on its digital LCD. Audible alerts indicate when a sample has melted, allowing for accurate documentation.

Q: What are the benefits of RS232/USB connectivity and internal data storage?

A: RS232/USB interfaces allow users to log melting point data directly to a computer for secure storage and easy sharing. The internal memory stores up to 50 results, supporting efficient record keeping and traceability without manual paperwork.

Q: When should calibration be performed on this apparatus?

A: Regular calibration is recommended, especially before critical analyses or after maintenance. The user-calibratable feature allows for calibration with certified standards, ensuring consistently accurate melting point results.

Q: Where can this melting point apparatus be utilized?

A: It is suitable for laboratories in chemical and pharmaceutical industries, quality control departments, educational institutions, and research centers throughout India to determine melting points of various substances.

Q: What safety features are present on the Automatic Melting Point Apparatus?

A: The device incorporates overheat protection, error messaging, and an in-built cooling fan to ensure safe operation. These features safeguard both user and sample integrity during the heating process.

Q: How is sample visibility enhanced during the melting process?

A: A built-in LED light source illuminates the samples, offering clear visibility in the viewing window. This aids precise observation and identification of the melting phase for accurate measurement.

Q: What is the process for recording and retrieving melting point data?

A: After measurement, results are automatically stored in internal memory. Users can export data using the RS232/USB port or print directly via the printer port for records, research, or compliance with regulations.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in General Laboratory Equipment Category

Lensometer Single Target For Medical lab

Lensometer Single Target For Medical lab

Price 7500 INR / Piece

Minimum Order Quantity : 1 Piece

Temperature Range : Room Temperature

Weight : Approx. 3.5 kg

Type : Lensometer

Usage : Optical Lens Measurement

K  Constant Spring For Physics Lab

K Constant Spring For Physics Lab

Price 3000.00 INR / Piece

Minimum Order Quantity : 01 Piece

Temperature Range : 0C to 50C

Weight : Approx. 200 grams

Type : Physics Experiment Lab Apparatus

Usage : Physics laboratory, K Constant experiments

Clamp Co-Axial (Three prong) Brass moulding jaws For Chemistry Lab

Clamp Co-Axial (Three prong) Brass moulding jaws For Chemistry Lab

Price 544 INR / Piece

Minimum Order Quantity : 1 Piece

Temperature Range : Ambient to 120C (dependent on application)

Weight : Approx. 120160 g

Type : ThreeProng CoAxial Clamp

Usage : Holding laboratory glassware, burettes, test tubes, condensers

Three Prong Brass Clamp For Chemistry Lab

Three Prong Brass Clamp For Chemistry Lab

Price 272 INR / Piece

Minimum Order Quantity : 1 Piece

Temperature Range : Up to 200C (depends on experiment setup)

Weight : Approx. 120160 grams

Type : Three Prong Brass Clamp

Usage : Used in chemistry labs for securely holding flasks, burettes, or glassware to a retort stand



Back to top