Melting Point Apparatus Automatic
Melting Point Apparatus Automatic

Melting Point Apparatus Automatic

Melting Point Apparatus Automatic Specification

  • Core Components
  • Microprocessor controlled system, Display, Heating block
  • Voltage
  • 220V AC
  • Feature
  • Programmable ramp rates, Digital Temperature Setting, In-built cooling fan, Audible alert on melting
  • Temperature Range
  • Room temperature to 320°C
  • Power Source
  • Electrical, corded
  • Accuracy
  • ±1°C
  • Automation Grade
  • Automatic
  • Measurement Range
  • Ambient to 320°C
  • Model No
  • Automatic-MPA-2024
  • Frequency
  • 50 Hz
  • Capacity
  • 3 samples simultaneously
  • Equipment Materials
  • Stainless Steel Body with Powder Coating
  • Type
  • Automatic Melting Point Apparatus
  • Usage
  • Melting point determination of chemicals and pharmaceutical substances
  • Display Type
  • Digital LCD display
  • Dimension (L*W*H)
  • 305 x 220 x 310 mm
  • Weight
  • approx. 7-8 kg
  • Calibration
  • User-calibratable
  • Timer
  • Digital timer integrated
  • Heating Rate
  • Selectable (0.5°C - 10°C per minute)
  • Safety Feature
  • Overheat protection and error messaging
  • Light Source
  • Built-in LED illumination for sample visibility
  • Interface
  • RS232/USB connectivity for data logging
  • Data Storage
  • Yes, internal memory up to 50 results
  • Sample Capacity
  • 3-4 capillary tubes
  • Printer Port
  • Yes
 
 

About Melting Point Apparatus Automatic

Auto Melting Point Apparatus is fabricated using the latest microcontroller technology and advanced engineering techniques. It features microcontroller based digital display and soft touch membrane type keys ensuring accurate display of results and easy operation. Also, Auto Melting Point Apparatus has programmable plateau temperature and heating ramp rates. Further, Auto Melting Point Apparatus facilitates storage of up to 100 results.

Features :

  • Easy to operate
  • 4 digit seven segment LED display
  • Programmable plateau temperature
  • Programmable ramp rates
  • Storage up to 100 results
  • Quick cooling with integrated fan
  • Audio visual indicators for system status


Advanced Sample Capacity and Efficient Workflow

This apparatus allows the simultaneous testing of three to four capillary tubes, improving laboratory throughput and minimizing wait times. Its programmable ramp rates, digital temperature settings, and audible alerts streamline melting point measurements for quick, reproducible results.


Reliable Connectivity and Data Management

Equipped with RS232/USB interface and printer port, the instrument enables hassle-free data logging and result export. Internal storage for up to 50 melting point results ensures comprehensive documentation and easy retrieval during audits or analysis.


Enhanced Safety and User Convenience

User safety is prioritized with overheat protection, error messaging, and an in-built cooling fan. The apparatus features a stainless steel powder-coated body, digital LCD screen for clear monitoring, and LED illumination for optimal sample visibility, aiding precise observation during analysis.

FAQ's of Melting Point Apparatus Automatic:


Q: How does the Automatic Melting Point Apparatus determine melting points of samples?

A: The apparatus uses up to three capillary tubes loaded with samples, heats them at a programmable rate, and displays melting observations on its digital LCD. Audible alerts indicate when a sample has melted, allowing for accurate documentation.

Q: What are the benefits of RS232/USB connectivity and internal data storage?

A: RS232/USB interfaces allow users to log melting point data directly to a computer for secure storage and easy sharing. The internal memory stores up to 50 results, supporting efficient record keeping and traceability without manual paperwork.

Q: When should calibration be performed on this apparatus?

A: Regular calibration is recommended, especially before critical analyses or after maintenance. The user-calibratable feature allows for calibration with certified standards, ensuring consistently accurate melting point results.

Q: Where can this melting point apparatus be utilized?

A: It is suitable for laboratories in chemical and pharmaceutical industries, quality control departments, educational institutions, and research centers throughout India to determine melting points of various substances.

Q: What safety features are present on the Automatic Melting Point Apparatus?

A: The device incorporates overheat protection, error messaging, and an in-built cooling fan to ensure safe operation. These features safeguard both user and sample integrity during the heating process.

Q: How is sample visibility enhanced during the melting process?

A: A built-in LED light source illuminates the samples, offering clear visibility in the viewing window. This aids precise observation and identification of the melting phase for accurate measurement.

Q: What is the process for recording and retrieving melting point data?

A: After measurement, results are automatically stored in internal memory. Users can export data using the RS232/USB port or print directly via the printer port for records, research, or compliance with regulations.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in General Laboratory Equipment Category

Piston Recorder

Piston Recorder

Price 700 INR / Piece

Minimum Order Quantity : 1 Piece

Dimension (L*W*H) : 275 mm x 275 mm x 350 mm

Equipment Materials : Mild Steel Body, Corrosion Resistant Finish

Capacity : 250 ml to 1000 ml

Model No : PRX01

Air Sampler

Air Sampler

Price 162000 INR / Piece

Minimum Order Quantity : 1 Piece

Dimension (L*W*H) : 22 cm x 16 cm x 20 cm

Equipment Materials : Stainless Steel & ABS Plastic

Capacity : 100 L/min

Model No : AS100

Discharge Over Notches Apparatus

Discharge Over Notches Apparatus

Price 22000 INR / Piece

Minimum Order Quantity : 1 Piece

Dimension (L*W*H) : 600 x 250 x 180 Millimeter (mm)

Equipment Materials : Stainless Steel

Capacity : Slump tank 25 Liter/day

Crucible Tong For Physics Lab

Crucible Tong For Physics Lab

Minimum Order Quantity : 1 Piece

Dimension (L*W*H) : Common lengths: 6, 8, 10, 12

Equipment Materials : Mild Steel or Stainless Steel

Capacity : Suitable for holding various sizes of crucibles (typically smallmedium crucibles)

Model No : Depends on supplier; generic models available



Back to top