Lagged Pipe Apparatus
Lagged Pipe Apparatus

Lagged Pipe Apparatus

Price 50000 INR/ Piece

MOQ : 1 Piece

Lagged Pipe Apparatus Specification

  • Measuring Range
  • Variable temperature and heat transfer rates
  • Temperature
  • Ambient to 100°C
  • Display Type
  • Analog/Digital
  • Operating Voltage
  • 220-240V 50Hz
  • Number of Specimens
  • Single pipe
  • Application
  • Heat transfer experiments
  • Test Range
  • Heat transfer testing
  • Mounting Type
  • Bench-mounted
  • Specimen Size
  • Lagged pipe diameter ~ 1-2 inches
  • Power Supply
  • Electric
  • Features
  • Table-mounted design with insulated pipe section
  • Usage
  • Educational and research purposes
  • Capacity
  • Standard
  • Machine Weight
  • Approximately 50 kg
  • Control Mode
  • Manual
 
 

About Lagged Pipe Apparatus



The Lagged Pipe Apparatus is an essential tool for conducting heat transfer experiments. Designed to accommodate lagged pipes with a diameter of approximately 1-2 inches, this apparatus operates in a manual control mode. With a measuring range that includes variable temperature settings and heat transfer rates, it is suitable for a wide range of testing requirements. This apparatus features a table-mounted design with an insulated pipe section for efficient and accurate testing. It is bench-mounted for stability and has an operating voltage of 220-240V 50Hz. The electric power supply enables seamless operation for educational and research purposes. The apparatus can handle a single pipe specimen and offers a temperature range from ambient to 100C.

FAQs of Lagged Pipe Apparatus:


Q: What is the Specimen Size supported by the Lagged Pipe Apparatus?

A: The Lagged Pipe Apparatus supports lagged pipes with a diameter of approximately 1-2 inches.

Q: What is the Control Mode of the Lagged Pipe Apparatus?

A: The Lagged Pipe Apparatus operates in a manual control mode.

Q: What are the features of the Lagged Pipe Apparatus?

A: The apparatus features a table-mounted design with an insulated pipe section for efficient testing.

Q: What is the Operating Voltage requirement for the Lagged Pipe Apparatus?

A: The Lagged Pipe Apparatus operates at 220-240V 50Hz.

Q: What is the application of the Lagged Pipe Apparatus?

A: The Lagged Pipe Apparatus is used for conducting heat transfer experiments for educational and research purposes.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Mechanical Engineering Laboratory Equipment Category

COMBINED FLOW REACTOR (Compressed Air Feed System)

COMBINED FLOW REACTOR (Compressed Air Feed System)

Price 163000.0 INR / Unit

Minimum Order Quantity : 1 Unit

Usage : Laboratory/Industrial

Temperature : Room temperature to 50C

Accuracy : 0.5%

Interface Type : RS232/USB

Computerized Mechanical Heat Pump Test Rig

Computerized Mechanical Heat Pump Test Rig

Price 597375 INR / Piece

Minimum Order Quantity : 01 Piece

Usage : Educational Laboratory & Industrial Testing

Temperature : Ambient to 70C

Accuracy : 1%

Interface Type : USB/RS232 (Computer Interface)

PLUG FLOW TUBULAR REACTOR (Straight Tube Type & Compressed AirFeed System) (OP-102)

PLUG FLOW TUBULAR REACTOR (Straight Tube Type & Compressed AirFeed System) (OP-102)

Price 160000.0 INR / Unit

Minimum Order Quantity : 1 Unit

Usage : Laboratory educational & research analysis

Temperature : Ambient to 100C (depends on jacket/fluid)

Accuracy : 2% (Flow Meter), 1C (Temperature)

Interface Type : Analog/Digital I/O on control panel

ISOTHERMAL CONTINUOUSLY (CompressedAir Feed System) STIRRED TANK REACTOR (

ISOTHERMAL CONTINUOUSLY (CompressedAir Feed System) STIRRED TANK REACTOR (

Price 158640.0 INR

Minimum Order Quantity : 1

Usage : Research, Laboratory, Industrial Pilot Projects

Temperature : Ambient to 150C (Isothermal Control)

Accuracy : Temperature: 0.5C, Pressure: 0.1 bar

Interface Type : Analog/Digital, possible USB interface (optional)



Back to top