Pensky Marten Flash Point Apparatus
Pensky Marten Flash Point Apparatus

Pensky Marten Flash Point Apparatus

Price 7200 INR/ Piece

MOQ : 1 Piece

Pensky Marten Flash Point Apparatus Specification

  • Humidity
  • Ambient (up to 85% RH)
  • Accuracy
  • ±1°C
  • Port Size
  • Standard Aperture
  • Measuring Range
  • Ambient to 370°C
  • Test Range
  • Up to 370°C
  • Power Supply
  • 230 V AC, 50 Hz
  • Features
  • Sturdy construction, IS:1448 compliant, flame exposure & cover, insulated handle
  • Mounting Type
  • Benchtop
  • Specimen Size
  • 70-80 ml sample
  • Response Time
  • Immediate
  • Display Type
  • Analog/Digital Thermometer
  • Max Height
  • Approx 25 cm
  • Gas Pressure
  • Below 15 psi
  • Application
  • Determination of flash point of petroleum products
  • Operating Voltage
  • 230 V
  • Automation Grade
  • Manual
  • Frequency
  • 50 Hz
  • Temperature
  • Ambient to 370°C
  • Interface Type
  • Manual
  • Resolution
  • 0.1°C
  • Hardness
  • Brass Cup & Metallic Housing
  • Equipment Type
  • Pensky Marten Flash Point Apparatus
  • Number of Specimens
  • Single at a Time
  • Usage
  • Lab and Industrial
  • Capacity
  • 80 ml cup
  • Machine Weight
  • Approx 4-6 Kg
  • Test Speed
  • Manual Operation
  • Test Width
  • Standard Cup Diameter
  • Control Mode
  • Manual
  • Ignition Source
  • Gas or Electric Ignition
  • Maintenance
  • Easy to clean and assemble
  • Heating Rate
  • Controlled by regulator
  • Cup Coverage
  • Tight fitting lid reduces evaporation
  • Accessories Supplied
  • Thermometer, Test cup, test flame, power cord, manual
  • Insulation
  • Heat-resistant Bakelite handle
  • Color
  • Metallic (Silver/Gold)
  • Stirring Mechanism
  • Fixed speed mechanical stirrer
  • Burner Type
  • Gas or electrically heated
  • Safety Features
  • Heat shield, insulated cover
  • Standards Compliance
  • IS:1448 (Part 21), ASTM D93
  • Dimensions (LxWxH)
  • 250 x 200 x 250 mm (approx)
  • Material of Construction
  • Brass cup with stainless steel heating jacket
 

Pensky Marten Flash Point Apparatus Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Payment Terms
  • Letter of Credit (L/C), Telegraphic Transfer (T/T), Cash Advance (CA)
  • Supply Ability
  • 100 Pieces Per Day
  • Delivery Time
  • 1 Week
  • Packaging Details
  • STANDARD
  • Main Export Market(s)
  • Australia, North America, South America, Eastern Europe, Western Europe, Middle East, Central America, Asia, Africa
  • Main Domestic Market
  • All India
  • Certifications
  • ISO 9001-2015
 

Pensky Marten Flash Point Apparatus About



Discover a cost-effective and exclusive Pensky Marten Flash Point Apparatus, expertly crafted for ace performance in determining flash points of petroleum products. The resplendent design features a superb brass cup with a stainless steel heating jacket and sturdy insulation with a Bakelite handle, assuring safety and durability. Personalise your testing with manual control, electric or gas ignition, and a reliable mechanical stirrer. IS:1448 (Part 21) and ASTM D93 compliant, this apparatus boasts precise accuracy (1C), immediate response, and easy maintenance. Ideal for industrial and laboratory use.

Commercial Applications & Functional Features

The Pensky Marten Flash Point Apparatus is widely used in labs and industries for the accurate determination of flash point in petroleum products. Its sturdy metallic housing ensures longevity, while its resplendent brass cup and insulated handle provide safety and ergonomic handling. Other features include a heat shield, tight-fitting lid to minimize evaporation, and a user-friendly fixed-speed stirrermaking it superb for high-throughput testing environments.


Certifications, Payment, and Shipping Options

This apparatus meets stringent IS:1448 (Part 21) and ASTM D93 standards, ensuring top-notch test reliability. As a responsible exporter, importer, and service provider, we offer multiple payment terms and fast express shipping options. Freight arrangements are streamlined for bulk orders, and supply ability is robust to support large-scale laboratory or industrial needs across India and beyond. Certifications, prompt delivery, and aftersales services embody our commitment to customer satisfaction.


FAQs of Pensky Marten Flash Point Apparatus:


Q: How does the Pensky Marten Flash Point Apparatus ensure test accuracy?

A: The apparatus is compliant with IS:1448 (Part 21) and ASTM D93 standards, offers manual control, and features a high-resolution digital or analog thermometer for an accuracy of 1C within a measuring range of ambient to 370C.

Q: What kind of safety features are integrated in the device?

A: It includes a heat shield, insulated cover, and a Bakelite handle to provide protection during operation, ensuring both operator safety and equipment durability.

Q: Where is the Pensky Marten Flash Point Apparatus typically used?

A: This equipment is extensively used in laboratories and industrial settings for testing the flash point of petroleum products, helping organizations meet regulatory and safety standards.

Q: What accessories are provided with the apparatus upon purchase?

A: Each unit comes with a test cup, thermometer, test flame, power cord, and an operation manual to facilitate smooth installation and usage.

Q: How easy is it to clean and maintain the Pensky Marten Apparatus?

A: The apparatus is designed for ease of assembly and cleaning, reducing downtime and ensuring consistent performance in demanding environments.

Q: When should the flash point test be performed using this apparatus?

A: It is most commonly conducted during quality control processes, product development, or routine safety checks in the petroleum industry to ensure compliance with safety regulations.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Petroleum Testing Instruments Category

Tar Viscometer Multiple Apparatus

Tar Viscometer Multiple Apparatus

Price 20000 INR / Piece

Minimum Order Quantity : 1 Piece

Test Range : Tar viscosity measurement range as per IS: 1206

Measuring Range : Suitable for viscosity from 20 to 1000 seconds

Features : Simultaneous testing, corrosion resistant, stable stand

Accuracy : 0.5 seconds

Cloud And Pour Point Apparatus

Cloud And Pour Point Apparatus

Price 5500 INR / Piece

Minimum Order Quantity : 1 Piece

Test Range : 40C to +50C

Measuring Range : 40C to +50C

Features : Double walled insulating chamber, multibath capability, equipped for both cloud and pour point test per ASTM D97

Accuracy : 1C

Carbon Residue Apparatus (Conradson)

Carbon Residue Apparatus (Conradson)

Price 5000 INR / Piece

Minimum Order Quantity : 1 Piece

Test Range : Suitable for all types of petroleum products

Measuring Range : Up to 010% residue

Features : Heavy brass stand, nickel crucibles, porcelain dish, gas torch

Accuracy : Complies with IS 1448 P. 8 Method A

Aniline Point Apparatus

Aniline Point Apparatus

Price 6000 INR / Piece

Minimum Order Quantity : 1 Piece

Test Range : 50C to 150C

Measuring Range : Thermometer 0C to 150C

Features : Standard glassware, insulated handle, sturdy stand, precision thermometer

Accuracy : 1C



Back to top