Junkers Gas Calorimeter Apparatus
Junkers Gas Calorimeter Apparatus

Junkers Gas Calorimeter Apparatus

Price 73000 INR/ Piece

MOQ : 1 Piece

Junkers Gas Calorimeter Apparatus Specification

  • Mounting Type
  • Table-top
  • Operating Voltage
  • 230 V AC, 50 Hz
  • Test Range
  • Calorific Value: 400012000 kcal/m
  • Max Height
  • 600 mm
  • Gas Pressure
  • 0.5 to 2 bar
  • Equipment Type
  • Junkers Gas Calorimeter
  • Humidity
  • 10% to 90% RH (non-condensing)
  • Temperature
  • 5C to 50C (operating)
  • Number of Specimens
  • Single sample per operation
  • Interface Type
  • Manual
  • Accuracy
  • 1.5% of reading
  • Display Type
  • Glass tube scale (analog reading)
  • Frequency
  • 50 Hz
  • Automation Grade
  • Manual
  • Resolution
  • 10 kcal/m
  • Measuring Range
  • 4000 - 12000 kcal/m
  • Specimen Size
  • Not applicable (gaseous sample)
  • Features
  • Corrosion-resistant construction, precision flow meters, easy-to-read scale, safety flame arrestor, glass window
  • Port Size
  • Standard gas inlet, 12 mm
  • Application
  • Determining Calorific Value of Gaseous Fuels
  • Response Time
  • <10 minutes per test
  • Power Supply
  • 230 V AC, 50 Hz
  • Usage
  • Educational, Research, Laboratory, Industrial Fuel Testing
  • Capacity
  • Up to 2 litre/min gas flow
  • Machine Weight
  • Approx. 16 kg
  • Test Speed
  • Manual operation
  • Control Mode
  • Manual Control Valve
 

Junkers Gas Calorimeter Apparatus Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Payment Terms
  • Letter of Credit (L/C), Telegraphic Transfer (T/T), Cash Advance (CA)
  • Supply Ability
  • 100 Pieces Per Day
  • Delivery Time
  • 1 Week
  • Packaging Details
  • STANDARD
  • Main Export Market(s)
  • Australia, South America, Western Europe, Middle East, Central America, Asia, Eastern Europe, North America, Africa
  • Main Domestic Market
  • All India
  • Certifications
  • ISO 9001-2015
 

About Junkers Gas Calorimeter Apparatus



Buy the unprecedented Junkers Gas Calorimeter Apparatus, engineered for precision and durability using gorgeous SS304 stainless steel, borosilicate glass, and nickel-plated brass. Designed for manual operation, this marvelous table-top equipment measures calorific value of gaseous fuels with 1.5% accuracy and a resolution of 10 kcal/m. Grab yours now at an exclusive discount! Benefit from its corrosion-resistant construction and safety features, including a flame arrestor and water level indicator. Includes all essential accessories and supports a wide specimen compatibility. Ideal for laboratories, research facilities, and industrial fuel testing.

Junkers Gas Calorimeter Apparatus: Professional Fuel Testing

The Junkers Gas Calorimeter Apparatus is widely utilized in commercial, educational, and research settings to determine the calorific value of natural gas, LPG, coal gas, and more. The application method involves introducing a gaseous sample through the standard gas inlet and measuring its thermal output with precision. Used for industrial fuel analysis, laboratory instruction, and research, its versatility ensures reliability for single-sample, manual operations and rapid results in under 10 minutes.


Payment Terms, Sample Policy, and Packaging Details

Market value is preserved with secure packaging that promises safe arrival at your location. We offer transparent payment terms tailored to your requirements. Sample policies are available upon inquiry, ensuring you experience the apparatuss quality before purchase. Packaging includes robust protective materials and all necessary accessories. Fast and efficient delivery guarantees minimal downtime, letting you start experiments shortly after arrival.


FAQs of Junkers Gas Calorimeter Apparatus:


Q: How does the Junkers Gas Calorimeter Apparatus operate for fuel testing?

A: The apparatus operates manually, using a standard Bunsen-type burner and adjustable mixing to measure the calorific value of gaseous fuels. It uses a precise water flow rate and copper heat exchanger for accurate results.

Q: What types of gases can be tested with this calorimeter?

A: This device is compatible with natural gas, LPG, coal gas, coke oven gas, and biogas, making it versatile for various industrial and laboratory applications.

Q: When is the Junkers Gas Calorimeter best used in laboratory settings?

A: The calorimeter is ideal for fuel analysis experiments, educational demonstrations, and research projects, especially when accurate calorific values are needed within 10 minutes per test.

Q: Where is this apparatus typically installed for operation?

A: It is designed as a table-top unit, suitable for laboratories, research centers, educational institutions, and industrial fuel testing environments.

Q: What safety features does the apparatus include for secure operation?

A: Key safety features include a flame arrestor and water level indicator, ensuring safe and reliable measurements during operation.

Q: How is the sample introduced and the calorific value measured?

A: A gaseous sample is introduced via the standard inlet. The energy released is measured using supplied thermometers, a glass tube analog scale, and the calorimeter vessel.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Petroleum Testing Instruments Category

Pensky Martens (Semi Automatic)

Pensky Martens (Semi Automatic)

Price 60000 INR / Piece

Minimum Order Quantity : 1 Piece

Features : Auto stirrer, buzzer alarm, temperature control

Port Size : Standard cup configuration

Application : Determination of flash point of petroleum products

Resolution : 0.1C

Redwood Viscometer Multiple Apparatus

Redwood Viscometer Multiple Apparatus

Price 26000 INR / Piece

Minimum Order Quantity : 1 Piece

Features : Simultaneous Multiple Testing, IS: 1448 Part 1 compliant, Removable Jet, Water Bath heating arrangement

Port Size : Standard Redwood Jet Size

Application : Determination of kinematic viscosity of petroleum products

Resolution : 0.1 sec

Abel Flash Point Tester

Abel Flash Point Tester

Price 8500 INR

Minimum Order Quantity : 1 Piece

Features : Safe gas test flame, insulated handle, easy to use

Port Size : Standard

Application : Determines flash point of petroleum products

Resolution : 0.5C

REDWOOD VISCOMETER (1)

REDWOOD VISCOMETER (1)

Price 7800.0 INR / Piece

Minimum Order Quantity : 1 Piece

Features : Brass Oil Cup, Jet Orifice, Sturdy Frame

Port Size : Standard Orifice

Application : Measurement of Viscosity of Petroleum Products

Resolution : 1 Redwood Second



Back to top