About Aniline Point Apparatus
DDRI168 Aniline Point Apparatus as perIP 2&IS 1448 (P-3), ASTM D-611 Method Acomplete with jacket Elect heated with energy regular control (without thermometer) DDRI169A Aniline Point Apparatus as perIP-2method B ASTM D-611 By thin filmMethod BElect. heated with elect. Stirrer (without thermometer) DDRI 169B With Electronic Digital Temp. Controller
Precision Laboratory TestingEnsure accurate determination of the aniline point with high-standard components like borosilicate glassware, precision thermometer, and insulated features. Ideal for strictly manual, visual observation and compliant with international standards, this apparatus supports reliable petroleum product analysis.
Simple, Manual OperationThe Aniline Point Apparatus requires no external power source, operating solely on an alcohol or spirit lamp. Manual control provides flexibility and immediate visual response, making it straightforward for bench-top laboratory workflows.
Comprehensive Kit FeaturesEach unit comes with necessary accessories including a jacketed test tube, cooling bath, insulated beaker, test tube support, aniline bottle, measuring cylinder, and glass rod. Safety is enhanced with shielded heating and a heat-resistant handle.
FAQs of Aniline Point Apparatus:
Q: How is the Aniline Point Apparatus operated in a laboratory setting?
A: Operation is manual, using an alcohol or spirit lamp for heating. Users visually observe the sample during testing, adjusting the temperature and monitoring with the mercury-in-glass thermometer to determine the aniline point as per standard procedures.
Q: What types of materials are used in the construction of this apparatus?
A: The apparatus features borosilicate glass for chemical resistance, brass fittings for durability, and a mild steel stand for stability. Heat-resistant handles and a shielded heating element enhance user safety.
Q: When should the Aniline Point Apparatus be used for petroleum product testing?
A: This apparatus is intended for use during laboratory analysis of petroleum products, specifically when the aniline point needs to be determined according to ASTM D611 or IS 1448(P:18) standards.
Q: Where can this apparatus be mounted or used?
A: Designed for bench-top mounting, the Aniline Point Apparatus is suitable for laboratory environments, including educational institutions, industrial labs, and quality assurance facilities.
Q: What is the process for determining the aniline point using this kit?
A: The process involves mixing a measured amount of oil and aniline in the jacketed test tube, then heating it with the spirit lamp. The mercury-in-glass thermometer tracks the temperature, and visual observation confirms the aniline point as the sample reaches a defined cloudiness or clearing.
Q: What are the benefits of using a manual Aniline Point Apparatus for testing?
A: Manual operation allows for precise control and immediate response, complying with recognized standards. The robust construction assures durability, while safety features protect users during heating. No external power source is required, thus making it portable and easy to use.
Q: Can the apparatus accommodate different specimen sizes or perform tests under variable conditions?
A: The kit is optimized for one specimen (typically 50 ml oil + 10 ml aniline) at a time and supports testing within the 50C to 150C range under ambient laboratory conditions, adhering to standard testing protocols.